|
Compact bench top analysis system for production & research Applications.
|
- Process Monitoring
- In-Situ analysis
- Contamination Studies
- CVD / MOCVD
- Environmental Gas Analysis
- Thermal Analysis Mass Spectrometry
- Catalysis Studies / Reaction Kinetics
|
The HPR QIC-20 gas analysis system is a compact bench-top gas analysis system for monitoring gases and processes at pressures up to atmosphere, featuring:
- Robust, flexible, heated (up to 200°C) Quartz Inert Capillary (QIC).
- QIC direct inlet for <500ms response to gases / vapours.
- Continuous sampling of 1-20 cm3 / min from 10 mbar to 2 bar.
- High pressure sampling interface to 30 Bar available.
- Automated Flow Control Interface for constant ion source pressure.
- Liquid Nitrogen cryopanel for enhanced pumping of condensables.
- High Sensitivity (to 5 ppb), mass range to 510 amu.
- Soft Ionisation for the analysis of complex organics.
- Stability (less than ±0.5% height variation over 24 h).
- MASsoft control via RS232, RS485 or Ethernet LAN.
- Quantitative analysis methods.
Brochures
QIC Series Gas Analysers - Real-time Gas Analysis Systems (152K)
QIC Series Gas Analysers - System Configurations (636K)
QGA -Quantitative Gas Analysis
QIC Series Gas Analysers - Pressure and Temperature Sampling Options (703K)
Mass Spectrometers for Catalysis and Thermal Analysis (861K)
Connecting to TGA and Furnace Reactors (526K)

Application Notes
A Comparison of Positive and Negative Ion RGA Methods (534KB)
Analyis of Complex Gas and Vapour Mixtures from a Pyrolysis Gasifier (195K)
Detection and Analysis of Trace Impurities in Light Gases (164K)
Evolved Gas Analysis - The Study of Materials using TA-MS App Note 292 (324K)
High Performance Gas Analysis for Automotive Fuel Cell R&D (150K)
HPR20 Analysis of Motor Vehicle Exhaust Emissions (134K)
NOx Detection. The Detection of NO and NO2 using the HPR-20 (158KB)
NH3 Detection in H2O Vapour (174KB)
Quantative Analysis of Flourine-Containing Process Streams (191K)
Relative Sensitivity Measurements of Gases (114K)
Relative Sensitivity Measurements of Vapours (106K)
Soft Ionisation for Analysis of Complex Gas/Vapour Mixtures (383K)
Temperature Programmed Reduction with the QIC Series (329K)
Thermal Analysis - Mass Spectrometry (758K)
Thermal Analysis Study of a Pharmaceutical with Pyris 1 TGA and HPR 20 QIC Mass Spectrometer (218K)
Technical Information
Connecting to TGA and Furnace Reactors (526K)
Connecting with Hiden's HPR-20 QIC Gas Analysis System (526K)
GC Coupling with Hiden's HPR-20 QIC Gas Analysis System (162K)
HPR20 for Operando Experiments (148K)
In-Situ Thermal Analysis MS with the HPR-20 Solid Insertion Probe (874K)
Product Specification
QIC Dual Stream Capillary Connection Kit (427K)
Response Time for Hiden QIC Inlet (126K)
Stability Evaluation for Extended Measurement (185K)
Posters
Importance of an Optimised TA-MS Interface (459K)
Academic References
CATALYSIS - Selected Academic References (413K)
CATLAB - Selected Academic References (121K)
Gallery
    
   
  
|