Surgical Stent

For further information and pricing, please get in touch with us.

Stents are wireframe scaffolds, used to hold narrowed arteries open.

Surface condition of the stent is very important and SIMS can be used to examine the nanometre thick protective chromium dioxide layer which naturally forms on the material.

Overview

Stents are wireframe scaffolds, typically laser cut from stainless steel, use to hold narrowed arteries open. Inserted via a catheter, the mesh is placed in the narrow area and expanded using a small balloon which is then withdrawn.

Surface condition of the stent is very important, and SIMS can be used to examine the nanometre thick protective chromium dioxide layer which naturally forms on the material. The depth profiles below show how treating with a chlorine-based disinfecting product leaves the surface iron rich and open to corrosion, potentially causing failure or tissue damage.

Limit of Detection

SIMS is the surface analysis technique with the best limit of detection (LOD), often providing ppm and even ppb measurement. If no interfering signals are present, the actual limit of detection depends on the ionisation probability of the sought species, the transmission of the instrument and the analyte volume. Thus, as first two parameters are fixed, if the volume is very small, there will be insufficient atoms present for detection. By collecting the data as images, the pixel sizes can be summed laterally or over a number of cycles to effectively increase the analyte volume and improve the LOD. This means that lateral and depth resolutions can be mutually traded to optimise an analysis for the most desirable parameter.

Ion Beam Polarity and Chemistry

The secondary ions emitted from the specimen usually have a favoured polarity. For instance, alkali metals are emitted as positive ions and halogens as negative. The probability of ion formation is also enhanced by using oxygen for electropositive elements and caesium for electronegative elements. In addition, caesium can be used in the CsM+ mode, where the element of interest, M, is detected as a molecule with Cs. The CsM+ mode is an excellent means of detecting and quantifying metal oxides and other materials where both electropositive and electronegative elements are sought.

Stents may be coated with polymer layers for protection or to elute drugs into the region to prevent future blockage. Static SIMS can detect and characterise this layer.

Negative secondary ion image of the coated stent displays a very unifrom polymer layer

 

Further Reading

Icon

Electronic Structure and Catalytic Study of Solid Solutions of GaN in ZnO 48.00 KB 0 downloads

Electronic Structure and Catalytic Study of Solid Solutions of GaN in ZnO ...
Icon

Towards an Understanding of MCs+n Formation Mechanism in SIMS 1.94 MB 64 downloads

Towards an understanding of MCs+n formation mechanism in SIMS. ...
Icon

Surface Analysis under Ambient Conditions Using Plasma-Assisted Desorption/Ionization... 330.25 KB 46 downloads

Surface Analysis under Ambient Conditions Using Plasma-Assisted Desorption/Ionization...
Icon

Surface Analysis by Secondary-Ion Mass Spectroscopy During Etching with Gas-Cluster Ion Beam 153.58 KB 58 downloads

Surface analysis by secondary-ion mass spectroscopy during etching with gas-cluster...
Icon

Sputter Depth Profiling by Secondary Ion Mass Spectrometry Coupled with Sample Current... 613.21 KB 51 downloads

Sputter depth profiling by secondary ion mass spectrometry coupled with sample current...
Icon

Preparation and Characterization of Antimony-Doped Tin Dioxide Electrodes. 3. XPS and... 109.76 KB 46 downloads

Preparation and Characterization of Antimony-Doped Tin Dioxide Electrodes. 3. XPS...
Icon

Preferential Oxygen-Trapping in Metallic Multilayers: A SIMS Perspective 1.94 MB 49 downloads

Preferential Oxygen-Trapping in Metallic Multilayers: A SIMS Perspective. ...
Icon

Plasma Implanted Ultra Shallow Junction Boron Depth Profiles: Effect of Plasma Chemistry... 618.05 KB 53 downloads

Plasma implanted ultra shallow junction boron depth profiles: Effect of plasma chemistry...
Icon

Mass-Resolved Ion Scattering Spectrometry for Characterization of Samples with Historical... 200.29 KB 45 downloads

Mass-resolved ion scattering spectrometry for characterization of samples with historical...
Icon

Interfacial Diffusion in a Double Quantum Well Structure 1.94 MB 56 downloads

Interfacial diffusion in a double quantum well structure. ...